NKT6200-B
Keywords:
NKT6200-B
- Description
- Parameter
- Technology
- Applicable scope
-
- Commodity name: NKT6200-B
Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 1040mm × 505mm × 335mm Product Features: Fully intelligent one-button operation throughout the entire process; Forward and Reverse Fourier Composite Optical System; Ultra-high-speed Signal Acquisition System; LIMS Laser Intelligent Management System; High Accuracy and Resolution; Dry and Wet Modes Automatically Switchable with One Button (completed in 2 seconds).
Product Overview

The NKT6200-B is an upgraded version of the 6100-B, featuring higher measurement accuracy and a wider measurement range. It is specially designed for laboratories in large enterprises, universities, and research institutes, and is suitable for a variety of applications including powder-related research, new material development, powder quality control, and production process optimization. The instrument incorporates several innovative patented technologies and is equipped with a three-lens optical system, combined with NKT’s next-generation array of forward, side, and backward detectors, which significantly expands the measurement range and comprehensively enhances instrument performance. In terms of hardware, it adopts a fifth-generation ultra-high-speed acquisition motherboard, ensuring more comprehensive and precise collection of scattered signals. It boasts an industry-leading dry- and wet-method one-button switching system, enabling seamless mode transitions within just one second. Its uniquely developed Laser Intelligent Management System (LIMS) can further extend the theoretical lifespan of the laser indefinitely. The dry- and wet-method dispersion system features a pipeline design that leaves no residue and employs a direct-injection sampling method, effectively preventing the deposition of large particles and ensuring zero residual sample in the pipeline after testing. This design not only guarantees the accuracy of tests on different samples but also greatly improves the reproducibility of repeated measurements, ensuring that every measurement result is genuine and reliable.
Scope of Application
- Industrial minerals and powders: Non-metallic powders such as heavy calcium carbonate, talc, and kaolin, along with their aqueous/solvent-based suspensions; metal powders and slurries including aluminum, copper, and rare earth metals; dry building material raw materials such as cement, ceramic powders, and graphite powder, as well as ceramic slurries and graphene dispersions;
- Energy and Chemical Materials: Dry samples including lithium battery cathode and anode materials, catalysts, phosphors, rubber and plastic additives (powder form), magnetic powder for powder coatings, etc.; wet samples such as drilling fluids, battery slurries, catalyst suspensions, phosphor slurries, and rubber additive emulsions, etc.
- Pharmaceuticals and Biologics: Dry samples such as active pharmaceutical ingredient powders, ultrafine Chinese medicinal microgranules, spray-dried formulations, etc.; liquid-based samples such as pesticide suspensions, spray formulations, liposomes, protein-based vaccine adjuvants, etc.
- Food and Daily Chemicals: Dry samples such as starch, protein powder, powdered pigments, dye powders, and powdered cosmetic ingredients; wet samples such as dairy products, beverages, sauces, pigment pastes, dye solutions, coatings, inks, and emulsions.
- Environment and Geology: Dry samples such as dust, aerosols, soil particles, and dried sediment samples; wet samples such as silt, suspended particles in sediments, water treatment flocs, and environmental water samples.
- New Materials and Specialized Industries: Dry samples including 3D-printing powders, laser cladding powders, metal micropowders, gunpowder powders, nano-ceramic powders, as well as wet samples such as carbon nanotube dispersions, nano-silver sols, graphene oxide solutions, and polymer composite slurries.
Product Parameters
Measurement principle
Full-range laser diffraction
Particle size range
0.1 μm – 3000 μm / 0.01 μm – 3000 μm (full-range testing)
Detection system
146/157-channel uniform cross-over and area-compensated multi-orientation array
Switching method
Dry and wet modes can be automatically switched with one touch, completing all switching operations in as little as 2 seconds—no manual intervention required.
Dual laser
Imported high-performance laser, wavelength 635 nm (optional wavelengths: 639 nm, 650 nm), power 20 mW (adjustable); imported high-power semiconductor laser, wavelength 405 nm, power 20 mW.
Laser Management
LIMS Laser Intelligent Management System
Optical model
Mie scattering theory over the entire measurement range, including a high-concentration multi-scattering dynamic compensation technique.
Filtering method
Dual-lens filtering technology: Fourier transform lens + filtering lens
Collect the motherboard
Sixth-generation 16-bit, 200 kbps ultra-high-speed simultaneous acquisition motherboard
Concentration range
Minimum shading rate: 3%; maximum shading rate: 90% (optical density)
Sample pool
Processed with a special coating technology, the optical signal transmittance exceeds 99.7%.
Protection function
Ultrasound dry-run protection, liquid-level sensor, overflow pipe, and no response to misoperations.
Ultrasound power
50W/60W optional; optional adjustable-power ultrasonic unit available.
Alignment system
Mechanical Center + Optical Center Dual-Positioning Fully Automatic Centering System
Measure time
Typical value < 10 seconds
Measurement accuracy
Accuracy and repeatability Dv50 are both better than ±0.5% (NIST-traceable standard sample).
Measurement method
Wet-method SOP with editable, fully automatic measurement; dry-method with one-click, fully automatic measurement.
Ambient temperature
0°C–45°C
Environmental humidity
10%-85% relative humidity (no condensation)
Power requirements
220V (±20V), 50Hz–60Hz
Implementation standard
ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022
External dimensions
1040mm × 505mm × 335mm
Instrument weight
50kg
Technical Explanation
One-click intelligent testing for the entire process—extremely simplified operation, consistent results.
The instrument features a built-in, editable Standard Operating Procedure (SOP) that, with just one click, automatically executes the entire testing process—from water intake and bubble removal to background measurement, sample dispersion, data acquisition, storage, and cleaning. By delegating complex operations to the instrument itself, operators only need to place the sample into the device, significantly reducing reliance on operator experience. This mode completely eliminates the inevitable variations and subjective errors inherent in manual operations, ensuring high consistency and reliability of test data across different operators and at different time points—perfectly aligning with GLP laboratory standards and quality traceability system requirements.
A one-touch, seconds-level switching system for wet and dry processes—ultra-fast switching with seamless integration.
Equipped with an industry-leading dry-and-wet mode one-click switching system, the software can complete a seamless transition between test modes within just one second, eliminating the need for any hardware changes or waiting periods. Users can immediately switch from dry-mode testing to wet-mode analysis, completely breaking down traditional barriers to mode switching and significantly enhancing detection efficiency and instrument usability.
LIMS Laser Intelligent Management System—Smart Optical Paths, Forever Stable
The system integrates an advanced LIMS laser intelligent management system, enabling precise and intelligent control of laser sources. It can monitor the optical path status in real time, instantly activate the laser upon receiving a test command, and quickly reach a stable operating state within 3 seconds—greatly reducing wait times and boosting detection efficiency. After measurement is complete, the system automatically shuts down the laser, completely eliminating unnecessary standby power consumption. This intelligent management technology effectively prevents light degradation caused by prolonged laser operation, significantly extending the service life of core components. In theory, the design allows lasers to operate without replacement for their entire lifespan, delivering customers unparalleled reliability and ultra-low maintenance costs.
Ultra-High-Speed Signal Acquisition System—Capturing Transients, Gaining Insights at the Nanoscale
Equipped with a fifth-generation ultra-high-speed signal acquisition motherboard, the system achieves an ultra-high sampling rate of 10,000 times per second. Thanks to this hardware-level breakthrough, the system can complete comprehensive, lossless, and synchronous capture of all particle-scattered light signals within the fleeting 0.1-second interval when a sample passes through the measurement zone. This completely resolves the issue of signal omission caused by the random orientation of particles, thereby ensuring unparalleled accuracy and high repeatability in particle size distribution results.
Positive and Negative Fourier Composite Optical System—Three Lenses Working in Synergy, Accurate as One
Employing an original composite optical path based on forward and inverse Fourier transformations, this system integrates a Fourier collimating lens, a filtering lens, and a standard Fourier transform lens to form a high-performance three-lens optical system. The entire optical path is meticulously designed to ensure precision and stability, providing a solid foundation for the highly accurate measurement of core particle size parameters.
Sixth-generation long-life, highly stable photoelectric detector—crafted with meticulous R&D, ensuring consistent precision.
The core photoelectric detector array is equipped with NKT’s independently developed sixth-generation highly stable photoelectric detector. It uses specially selected, high-performance raw materials imported from Germany and boasts exceptional antioxidant and anti-aging properties, ensuring that the photoelectric conversion efficiency remains virtually unchanged for up to ten years. The detector’s theoretical lifespan is synchronized with that of the entire instrument, eliminating the need for replacement throughout its lifetime and fundamentally guaranteeing long-term consistency and accuracy of the instrument’s measurement data, as well as extremely low lifetime maintenance costs.
Intelligent Real-Time Dew Point Monitoring and Early Warning System—Gain Insight, Prevent Problems Before They Arise
Specifically designed to ensure the measurement accuracy of laser particle size analyzers even in harsh environmental conditions, this system integrates high-precision sensors with intelligent algorithms. It can monitor in real time the microenvironmental conditions within the instrument’s core optical system and proactively predict the risk of condensation. By issuing timely risk-control alerts, it enables proactive intervention before physical phenomena occur, fundamentally preventing light scattering data deviations caused by condensation on the optical window and ensuring the authenticity and accuracy of particle size distribution results.
Sample design with zero residue—zero residues, real data.
An innovative flow-path system design has been adopted, enabling a comprehensive optimization of pipeline layout and drainage structure. At the heart of this system is a self-cleaning circulation pump featuring patented technology; its unique structural design and hydrodynamic optimization ensure that, upon completion of testing, no residual liquid remains in either the pipelines or the pump body. This breakthrough completely resolves the longstanding challenge of cross-contamination caused by sample residues in conventional instruments, thereby guaranteeing the independence and absolute accuracy of each test result from the very foundation of the hardware. As a result, the instrument’s test reproducibility and reliability have been significantly enhanced.
Misoperation Protection System—Smart Protection, Fearless of Mistakes
Equipped with a comprehensive, intelligent fail-safe protection system that integrates hardware interlocks and software-based intelligent detection. The system can detect non-compliant operations in real time and immediately trigger proactive alerts and interrupt execution. It will not respond to invalid commands at all, thereby fundamentally preventing instrument hardware damage caused by human error and significantly enhancing the device’s durability and operational safety, allowing you to use it with complete peace of mind.
Professional-grade dustproof and shockproof design—unafraid of environmental fluctuations, ensuring data remains consistently reliable.
Equipped with a professional, integrated, sealed dust-proof system and an anti-vibration design, this product effectively prevents external dust from entering and minimizes the transmission of vibrations. This design ensures long-term stability and precise focusing of the core optical path system, eliminating the need for manual adjustment of the detector position. As a result, maintenance frequency is significantly reduced, guaranteeing ultra-high repeatability and reliability of measurement results—even under challenging industrial conditions.
Multi-Impact Dry Dispersion Technology—Efficient Deagglomeration, Powerful Dispersion
Employing a multi-impact dry dispersion technology, the process uses high-speed airflow to guide powder particles through multi-stage physical collisions, effectively breaking up ultrafine and agglomerated powders into their individual particles. This ensures that particles pass through the detection zone in a monodisperse state, significantly enhancing the accuracy and repeatability of ultrafine dry powder measurements.
Sample Window Quick-Change System—Revolutionary Design, Operation in Seconds
Equipped with a revolutionary sample window quick-change mechanism, this device features a user-friendly snap-lock and guiding structure design. Without the need for any tools, users can independently complete the entire process of removing and installing the sample window in just 10 seconds, greatly simplifying the maintenance procedure, significantly reducing instrument maintenance time, and ensuring continuous operational efficiency in high-throughput testing environments.
Intelligent Multi-dimensional Reporting and Analytics System—Flexible, Efficient, Intelligent, and Intuitive
Equipped with professional-grade particle size analysis software, this system integrates a robust database and a multi-dimensional reporting system. It supports exporting reports in multiple formats and allows for customized editing. Additionally, it features simultaneous comparison of multiple datasets on a single screen, significantly enhancing data interpretation efficiency and report-generation flexibility, thereby fully meeting the requirements of scientific research, quality control, and compliance.
High repeatability
The NKT6200-B boasts excellent repeatability; its measurement results remain highly consistent across multiple experiments, with error margins typically kept within an extremely narrow range. This outstanding repeatability stems from the instrument’s meticulously designed optical system and stable laser source, which ensure that the conditions for collecting particle-scattered light signals remain identical every time a test is performed. Whether analyzing consecutive batches of samples or measuring the same sample at different time points, the laser particle size analyzer consistently delivers stable and reliable particle size distribution data. It effectively eliminates the impact of human operational variability and environmental fluctuations on the results, providing robust data support for quality control in both scientific research and industrial production.

High accuracy and resolution
The NKT6200-B boasts excellent accuracy and resolution. Thanks to its precise optical system and advanced data-processing algorithms, it can perform highly accurate particle-size distribution measurements on particulate samples. In terms of accuracy, this instrument employs a stable laser source that ensures uniform and consistent beam intensity. Coupled with a sophisticated detector array, it can keep measurement errors within an extremely narrow range—typically within ±0.5%—thus accurately reflecting the true particle-size characteristics of the sample. As for resolution, the laser particle-size analyzer can clearly distinguish between particle populations of different sizes, even detecting subtle differences in particle size with remarkable effectiveness. Its resolution can reach as fine as 0.01 micrometers, making it capable of meeting measurement requirements across a broad particle-size range—from nanometer-scale to millimeter-scale particles.

Multi-peak resolution
NKT's latest software integrates powerful features such as multi-peak resolution algorithms, dynamic compensation algorithms, and noise recognition.

The above figure shows that testing on actual samples (non-standard samples) better reflects the customer’s actual needs.

The above figure shows the test results for a sample with a broad distribution.

The above image shows the customer’s sample (non-standard sample).
Complies with the latest pharmacopoeia requirements
Software solutions that comply with the GMP Annex “Computerized Systems” requirements, featuring electronic signatures, user-level classification, access control, security policies, log management, data integrity, and traceability capabilities.

-
Product Parameters
Measurement principle
Full-range laser diffraction
Particle size range
0.1 μm – 3000 μm / 0.01 μm – 3000 μm (full-range testing)
Detection system
146/157-channel uniform cross-over and area-compensated multi-orientation array
Switching method
Dry and wet modes can be automatically switched with one touch, completing all switching operations in as little as 2 seconds—no manual intervention required.
Dual laser
Imported high-performance laser, wavelength 635 nm (optional wavelengths: 639 nm, 650 nm), power 20 mW (adjustable); imported high-power semiconductor laser, wavelength 405 nm, power 20 mW.
Laser Management
LIMS Laser Intelligent Management System
Optical model
Mie scattering theory over the entire measurement range, including a high-concentration multi-scattering dynamic compensation technique.
Filtering method
Dual-lens filtering technology: Fourier transform lens + filtering lens
Collect the motherboard
Sixth-generation 16-bit, 200 kbps ultra-high-speed simultaneous acquisition motherboard
Concentration range
Minimum shading rate: 3%; maximum shading rate: 90% (optical density)
Sample pool
Processed with a special coating technology, the optical signal transmittance exceeds 99.7%.
Protection function
Ultrasound dry-run protection, liquid-level sensor, overflow pipe, and no response to misoperations.
Ultrasound power
50W/60W optional; optional adjustable-power ultrasonic unit available.
Alignment system
Mechanical Center + Optical Center Dual-Positioning Fully Automatic Centering System
Measure time
Typical value < 10 seconds
Measurement accuracy
Accuracy and repeatability Dv50 are both better than ±0.5% (NIST-traceable standard sample).
Measurement method
Wet-method SOP with editable, fully automatic measurement; dry-method with one-click, fully automatic measurement.
Ambient temperature
0°C–45°C
Environmental humidity
10%-85% relative humidity (no condensation)
Power requirements
220V (±20V), 50Hz–60Hz
Implementation standard
ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022
External dimensions
1040mm × 505mm × 335mm
Instrument weight
50kg
-
Technical Explanation
One-click intelligent testing for the entire process—extremely simplified operation, consistent results.The instrument features a built-in, editable Standard Operating Procedure (SOP) that, with just one click, automatically executes the entire testing process—from water intake and bubble removal to background measurement, sample dispersion, data acquisition, storage, and cleaning. By delegating complex operations to the instrument itself, operators only need to place the sample into the device, significantly reducing reliance on operator experience. This mode completely eliminates the inevitable variations and subjective errors inherent in manual operations, ensuring high consistency and reliability of test data across different operators and at different time points—perfectly aligning with GLP laboratory standards and quality traceability system requirements.
A one-touch, seconds-level switching system for wet and dry processes—ultra-fast switching with seamless integration.Equipped with an industry-leading dry-and-wet mode one-click switching system, the software can complete a seamless transition between test modes within just one second, eliminating the need for any hardware changes or waiting periods. Users can immediately switch from dry-mode testing to wet-mode analysis, completely breaking down traditional barriers to mode switching and significantly enhancing detection efficiency and instrument usability.
LIMS Laser Intelligent Management System—Smart Optical Paths, Forever StableThe system integrates an advanced LIMS laser intelligent management system, enabling precise and intelligent control of laser sources. It can monitor the optical path status in real time, instantly activate the laser upon receiving a test command, and quickly reach a stable operating state within 3 seconds—greatly reducing wait times and boosting detection efficiency. After measurement is complete, the system automatically shuts down the laser, completely eliminating unnecessary standby power consumption. This intelligent management technology effectively prevents light degradation caused by prolonged laser operation, significantly extending the service life of core components. In theory, the design allows lasers to operate without replacement for their entire lifespan, delivering customers unparalleled reliability and ultra-low maintenance costs.
Ultra-High-Speed Signal Acquisition System—Capturing Transients, Gaining Insights at the NanoscaleEquipped with a fifth-generation ultra-high-speed signal acquisition motherboard, the system achieves an ultra-high sampling rate of 10,000 times per second. Thanks to this hardware-level breakthrough, the system can complete comprehensive, lossless, and synchronous capture of all particle-scattered light signals within the fleeting 0.1-second interval when a sample passes through the measurement zone. This completely resolves the issue of signal omission caused by the random orientation of particles, thereby ensuring unparalleled accuracy and high repeatability in particle size distribution results.
Positive and Negative Fourier Composite Optical System—Three Lenses Working in Synergy, Accurate as OneEmploying an original composite optical path based on forward and inverse Fourier transformations, this system integrates a Fourier collimating lens, a filtering lens, and a standard Fourier transform lens to form a high-performance three-lens optical system. The entire optical path is meticulously designed to ensure precision and stability, providing a solid foundation for the highly accurate measurement of core particle size parameters.
Sixth-generation long-life, highly stable photoelectric detector—crafted with meticulous R&D, ensuring consistent precision.The core photoelectric detector array is equipped with NKT’s independently developed sixth-generation highly stable photoelectric detector. It uses specially selected, high-performance raw materials imported from Germany and boasts exceptional antioxidant and anti-aging properties, ensuring that the photoelectric conversion efficiency remains virtually unchanged for up to ten years. The detector’s theoretical lifespan is synchronized with that of the entire instrument, eliminating the need for replacement throughout its lifetime and fundamentally guaranteeing long-term consistency and accuracy of the instrument’s measurement data, as well as extremely low lifetime maintenance costs.
Intelligent Real-Time Dew Point Monitoring and Early Warning System—Gain Insight, Prevent Problems Before They AriseSpecifically designed to ensure the measurement accuracy of laser particle size analyzers even in harsh environmental conditions, this system integrates high-precision sensors with intelligent algorithms. It can monitor in real time the microenvironmental conditions within the instrument’s core optical system and proactively predict the risk of condensation. By issuing timely risk-control alerts, it enables proactive intervention before physical phenomena occur, fundamentally preventing light scattering data deviations caused by condensation on the optical window and ensuring the authenticity and accuracy of particle size distribution results.
Sample design with zero residue—zero residues, real data.An innovative flow-path system design has been adopted, enabling a comprehensive optimization of pipeline layout and drainage structure. At the heart of this system is a self-cleaning circulation pump featuring patented technology; its unique structural design and hydrodynamic optimization ensure that, upon completion of testing, no residual liquid remains in either the pipelines or the pump body. This breakthrough completely resolves the longstanding challenge of cross-contamination caused by sample residues in conventional instruments, thereby guaranteeing the independence and absolute accuracy of each test result from the very foundation of the hardware. As a result, the instrument’s test reproducibility and reliability have been significantly enhanced.
Misoperation Protection System—Smart Protection, Fearless of MistakesEquipped with a comprehensive, intelligent fail-safe protection system that integrates hardware interlocks and software-based intelligent detection. The system can detect non-compliant operations in real time and immediately trigger proactive alerts and interrupt execution. It will not respond to invalid commands at all, thereby fundamentally preventing instrument hardware damage caused by human error and significantly enhancing the device’s durability and operational safety, allowing you to use it with complete peace of mind.
Professional-grade dustproof and shockproof design—unafraid of environmental fluctuations, ensuring data remains consistently reliable.
Equipped with a professional, integrated, sealed dust-proof system and an anti-vibration design, this product effectively prevents external dust from entering and minimizes the transmission of vibrations. This design ensures long-term stability and precise focusing of the core optical path system, eliminating the need for manual adjustment of the detector position. As a result, maintenance frequency is significantly reduced, guaranteeing ultra-high repeatability and reliability of measurement results—even under challenging industrial conditions.
Multi-Impact Dry Dispersion Technology—Efficient Deagglomeration, Powerful DispersionEmploying a multi-impact dry dispersion technology, the process uses high-speed airflow to guide powder particles through multi-stage physical collisions, effectively breaking up ultrafine and agglomerated powders into their individual particles. This ensures that particles pass through the detection zone in a monodisperse state, significantly enhancing the accuracy and repeatability of ultrafine dry powder measurements.
Sample Window Quick-Change System—Revolutionary Design, Operation in SecondsEquipped with a revolutionary sample window quick-change mechanism, this device features a user-friendly snap-lock and guiding structure design. Without the need for any tools, users can independently complete the entire process of removing and installing the sample window in just 10 seconds, greatly simplifying the maintenance procedure, significantly reducing instrument maintenance time, and ensuring continuous operational efficiency in high-throughput testing environments.
Intelligent Multi-dimensional Reporting and Analytics System—Flexible, Efficient, Intelligent, and Intuitive
Equipped with professional-grade particle size analysis software, this system integrates a robust database and a multi-dimensional reporting system. It supports exporting reports in multiple formats and allows for customized editing. Additionally, it features simultaneous comparison of multiple datasets on a single screen, significantly enhancing data interpretation efficiency and report-generation flexibility, thereby fully meeting the requirements of scientific research, quality control, and compliance.
High repeatabilityThe NKT6200-B boasts excellent repeatability; its measurement results remain highly consistent across multiple experiments, with error margins typically kept within an extremely narrow range. This outstanding repeatability stems from the instrument’s meticulously designed optical system and stable laser source, which ensure that the conditions for collecting particle-scattered light signals remain identical every time a test is performed. Whether analyzing consecutive batches of samples or measuring the same sample at different time points, the laser particle size analyzer consistently delivers stable and reliable particle size distribution data. It effectively eliminates the impact of human operational variability and environmental fluctuations on the results, providing robust data support for quality control in both scientific research and industrial production.

High accuracy and resolutionThe NKT6200-B boasts excellent accuracy and resolution. Thanks to its precise optical system and advanced data-processing algorithms, it can perform highly accurate particle-size distribution measurements on particulate samples. In terms of accuracy, this instrument employs a stable laser source that ensures uniform and consistent beam intensity. Coupled with a sophisticated detector array, it can keep measurement errors within an extremely narrow range—typically within ±0.5%—thus accurately reflecting the true particle-size characteristics of the sample. As for resolution, the laser particle-size analyzer can clearly distinguish between particle populations of different sizes, even detecting subtle differences in particle size with remarkable effectiveness. Its resolution can reach as fine as 0.01 micrometers, making it capable of meeting measurement requirements across a broad particle-size range—from nanometer-scale to millimeter-scale particles.

Multi-peak resolution
NKT's latest software integrates powerful features such as multi-peak resolution algorithms, dynamic compensation algorithms, and noise recognition.

The above figure shows that testing on actual samples (non-standard samples) better reflects the customer’s actual needs.

The above figure shows the test results for a sample with a broad distribution.

The above image shows the customer’s sample (non-standard sample).
Complies with the latest pharmacopoeia requirements
Software solutions that comply with the GMP Annex “Computerized Systems” requirements, featuring electronic signatures, user-level classification, access control, security policies, log management, data integrity, and traceability capabilities.

-
- Industrial minerals and powders: Non-metallic powders such as heavy calcium carbonate, talc, and kaolin, along with their aqueous/solvent-based suspensions; metal powders and slurries including aluminum, copper, and rare earth metals; dry building material raw materials such as cement, ceramic powders, and graphite powder, as well as ceramic slurries and graphene dispersions;
- Energy and Chemical Materials: Dry samples including lithium battery cathode and anode materials, catalysts, phosphors, rubber and plastic additives (powder form), magnetic powder for powder coatings, etc.; wet samples such as drilling fluids, battery slurries, catalyst suspensions, phosphor slurries, and rubber additive emulsions, etc.
- Pharmaceuticals and Biologics: Dry samples such as active pharmaceutical ingredient powders, ultrafine Chinese medicinal microgranules, spray-dried formulations, etc.; liquid-based samples such as pesticide suspensions, spray formulations, liposomes, protein-based vaccine adjuvants, etc.
- Food and Daily Chemicals: Dry samples such as starch, protein powder, powdered pigments, dye powders, and powdered cosmetic ingredients; wet samples such as dairy products, beverages, sauces, pigment pastes, dye solutions, coatings, inks, and emulsions.
- Environment and Geology: Dry samples such as dust, aerosols, soil particles, and dried sediment samples; wet samples such as silt, suspended particles in sediments, water treatment flocs, and environmental water samples.
- New Materials and Specialized Industries: Dry samples including 3D-printing powders, laser cladding powders, metal micropowders, gunpowder powders, nano-ceramic powders, as well as wet samples such as carbon nanotube dispersions, nano-silver sols, graphene oxide solutions, and polymer composite slurries.
Certification
High-tech Enterprise Certificate
Quality Management System Certification Certificate
Quality Management System Certification Certificate
CE certification
Factory
4
3
2
1
Exhibition event
4
3
2
1
FAQ
If you’re interested in this product, please fill out the following information and submit it to us. We’ll arrange for an expert to contact you as soon as possible!
Related products
Related products