Product Center

Professional manufacturer of intelligent analytical instruments

NKT2020-L
+
  • NKT2020-L

NKT2020-L

Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 700mm × 495mm × 330mm Product Features: Fully Intelligent One-Click Operation Throughout the Entire Process; Forward and Reverse Fourier Composite Optical System; Ultra-High-Speed Signal Acquisition System; Multi-Impact Dry Dispersion Technology; Intelligent Optical Dynamic Compensation Algorithm; LIMS Laser Intelligent Management System

Keywords:

NKT2020-L

  • Description
  • Parameter
  • Technology
  • Applicable scope
    • Commodity name: NKT2020-L

    Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 700mm × 495mm × 330mm Product Features: Fully Intelligent One-Click Operation Throughout the Entire Process; Forward and Reverse Fourier Composite Optical System; Ultra-High-Speed Signal Acquisition System; Multi-Impact Dry Dispersion Technology; Intelligent Optical Dynamic Compensation Algorithm; LIMS Laser Intelligent Management System

    Product Overview

    The NKT2020-L high-performance dry-method fully automatic laser particle size analyzer integrates cutting-edge international optical technology with intelligent automation, setting a new benchmark for precise particle size analysis. This instrument strictly adheres to the Mie scattering theory and features an original optical path design that combines forward and reverse Fourier composite optical transformations. It employs a three-lens optical system comprising a Fourier collimating lens, a filtering lens, and a standard Fourier transform lens, ensuring the precision and stability of the optical path throughout the entire process—from light source to signal detection—thus laying a solid foundation for highly accurate measurements. Equipped with a high-density photoelectric array probe and seamless full-range testing technology, the device achieves complete coverage of the detection range and ensures no signal is missed, guaranteeing exceptional accuracy and outstanding repeatability of test results. The unique dry dispersion system adopts a pipeline design with zero residue, effectively preventing particle deposition and residual accumulation. This not only ensures the accuracy of tests on different samples but also completely eliminates cross-contamination, enabling consistently high precision even in subsequent tests. The testing process is fully automated and intelligently controlled, requiring no manual intervention; a single click can complete the entire measurement procedure, significantly enhancing operational efficiency while ensuring more stable and reliable test results, thereby meeting the demands of high-end scientific research and stringent industrial quality control.

  • Product Parameters

    Measurement principle

    Mie Scattering Principle for the Full Measurement Range

    Measurement range

    0.1 μm – 1200 μm (full-range testing)

    Detection system

    96-channel uniform cross and area-compensated multi-orientation array

    Laser device

    High-power fiber-coupled semiconductor laser with a wavelength of 635 nm and a maximum output power of 20 milliwatts.

    Laser Management

    LIMS Laser Intelligent Management System

    Optical model

    Mie scattering theory over the entire measurement range, including a high-concentration multi-scattering dynamic compensation technique.

    Filtering method

    Three-lens technology: forward and inverse Fourier transform lenses + filtering lens

    Collect the motherboard

    16-bit, 200 kbps ultra-high-speed acquisition motherboard—next-generation simultaneous acquisition motherboard

    Concentration range

    Minimum shading rate: 3%, maximum shading rate: 90% (optical density)

    Sample injection method

    Dry-method fully automatic sample introduction

    Protection function

    Misoperation with no response

    Alignment system

    Mechanical Center + Optical Center Dual-Positioning Fully Automatic Centering System

    Measure time

    Typical value < 10 seconds

    Measurement accuracy

    Accuracy and repeatability Dv50 are both better than ±0.5% (NIST-traceable standard sample).

    Measurement method

    One-click fully automatic measurement

    Ambient temperature

    0°C–45°C

    Environmental humidity

    10%-85% relative humidity (no condensation)

    Power requirements

    220V (±20V), 50Hz–60Hz

    Implementation standard

    ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022

    External dimensions

    700mm × 495mm × 330mm

    Instrument weight

     35kg

  • Technical Explanation

    1 One-click intelligent testing for the entire process—extremely simplified operation, consistent results.

    The instrument features a built-in, editable Standard Operating Procedure (SOP) that, with just one click, automatically executes the entire testing process—from water intake and bubble removal to background measurement, sample dispersion, data acquisition, storage, and cleaning. By delegating complex operations to the instrument itself, operators need only place the sample into the device, significantly reducing reliance on operator experience. This mode completely eliminates the inevitable variations and subjective errors inherent in manual operations, ensuring high consistency and reliability of test data across different operators and at different time points—perfectly aligning with GLP laboratory standards and quality traceability system requirements.

    1 LIMS Laser Intelligent Management System—Smart Optical Paths, Enduring and Stable

    The system integrates an advanced LIMS laser intelligent management system, enabling precise and intelligent control of laser sources. It can monitor the optical path status in real time, instantly activate the laser upon receiving a test command, and quickly reach a stable operating state within 3 seconds—greatly reducing wait times and boosting detection efficiency. After measurement is complete, the system automatically shuts down the laser, completely eliminating unnecessary standby power consumption. This intelligent management technology effectively prevents light degradation caused by prolonged laser operation, significantly extending the service life of core components. In theory, the design allows the laser to operate without replacement for its entire lifespan, delivering customers unparalleled reliability and ultra-low maintenance costs.

    1 Ultra-High-Speed Signal Acquisition System—Capturing Transients, Gaining Insights into the Nanoscale

    Equipped with a fifth-generation ultra-high-speed signal acquisition motherboard, the system achieves an ultra-high sampling rate of 10,000 times per second. Thanks to this hardware-level breakthrough, the system can complete comprehensive, lossless, and synchronous capture of all particle-scattered light signals within the fleeting 0.1-second interval when a sample passes through the measurement zone. This completely resolves the issue of signal omission caused by the random orientation of particles, thereby ensuring unparalleled accuracy and high repeatability in particle size distribution results.

    1 Positive and Negative Fourier Composite Optical System—Three Lenses Working in Synergy, Accurate as One

    Employing an original composite optical path based on forward and inverse Fourier transformations, this system integrates a Fourier collimating lens, a filtering lens, and a standard Fourier transform lens to form a high-performance three-lens optical system. The entire optical path is meticulously designed to ensure precision and stability, providing a solid foundation for highly accurate measurement of core particle size parameters.

    1 Sixth-generation long-life, highly stable photoelectric detector—crafted with meticulous R&D, ensuring consistent precision.

    The core photoelectric detector array is equipped with NKT’s independently developed sixth-generation highly stable photoelectric detector. It uses specially selected, high-performance raw materials imported from Germany and boasts exceptional antioxidant and anti-aging properties, ensuring that the photoelectric conversion efficiency remains virtually unchanged over a period of ten years. The detector’s theoretical lifespan is synchronized with that of the entire instrument, eliminating the need for replacement throughout its lifetime and fundamentally guaranteeing the long-term consistency and accuracy of the instrument’s measurement data, as well as extremely low lifetime maintenance costs.

    1 Intelligent Optical Path Dual-Alignment System—One-Click Calibration, Dynamic Stability

    Pioneering a dual-centering optical path system that integrates both mechanical and optical centering technologies. This system enables one-click startup and instantaneous, precise centering, completely eliminating the need for tedious manual adjustments. Moreover, the system continuously monitors and automatically maintains the optimal state of the optical path throughout the entire operation, ensuring long-term stability of measurement results and high instrument reliability—truly making it effortless and worry-free.

    1  Intelligent Optical Dynamic Compensation Algorithm—Leveraging Algorithmic Intelligence to Break Through Concentration Limits

    Equipped with NKT’s pioneering intelligent optical dynamic compensation algorithm, this algorithm simultaneously performs real-time dual compensation for both optical anomalies in the diffraction Airy disk and changes in sample concentration, thereby overcoming the measurement limitations of conventional instruments. Even within an ultra-wide obscuration range of 3% to 90%, it can directly deliver accurate and reliable particle size distribution data without the need for repeated adjustments to sample concentration, greatly enhancing detection efficiency and data comparability.

    1 Misoperation Protection System — Smart protection, no fear of accidental operation.

    Equipped with a comprehensive, intelligent fail-safe protection system that integrates hardware interlocks and software-based intelligent detection. The system can detect non-compliant operations in real time and immediately trigger proactive alerts and interrupt execution. It will not respond to invalid commands at all, thereby fundamentally preventing instrument hardware damage caused by human error and significantly enhancing the device’s durability and operational safety, allowing you to use it with complete peace of mind.

    1 Multi-impact dry dispersion technology—efficient deagglomeration, powerful dispersion

    Employing a multi-impact dry dispersion technology, the process utilizes high-speed airflow to guide powder particles through multi-stage physical collisions, enabling efficient deagglomeration of ultrafine and easily agglomerated powders. This ensures that particles pass through the detection zone in a monodisperse state, significantly enhancing the accuracy and repeatability of ultrafine dry powder measurements.

    1 Professional-grade dustproof and shockproof design—unafraid of environmental fluctuations, ensuring data remains consistently reliable.

    Featuring a professional, integrated, sealed dust-proof system and an anti-vibration design, this solution effectively prevents external dust from entering and minimizes the transmission of vibrations. This design ensures long-term stability and precise focusing of the core optical path system, eliminating the need for manual adjustment of the detector position. As a result, maintenance frequency is significantly reduced, guaranteeing ultra-high repeatability and reliability of measurement results—even under challenging industrial conditions.

    1 Sample-free direct-injection system—precise direct injection, leaving nothing behind.

    Employing a precision stainless steel pipeline direct-injection dry sampling technique, coupled with an optimized gas-path design and advanced pipe-wall processing, this method ensures zero sample residue remains in the pipeline after testing. It completely eliminates the risk of cross-contamination, significantly enhancing the accuracy and repeatability of continuous data measurement—making it particularly well-suited for applications that are sensitive to particle size and require frequent testing.

    1 High-speed turbulent dry dispersion system—ultra-strong negative pressure, anti-sticking

    Equipped with a dry dispersion system optimized based on French turbulent flow dispersion pump theory, this system leverages the Venturi effect to generate ultra-strong negative pressure, enabling continuous and uniform sample introduction as well as highly efficient dispersion. It completely resolves the issue of powder particle agglomeration, ensuring accurate and reliable test results.

    1 Intelligent Multi-dimensional Reporting and Analytics System—Flexible, Efficient, Intelligent, and Intuitive

    Equipped with professional-grade particle size analysis software, this system integrates a robust database and a multi-dimensional reporting system. It supports exporting reports in multiple formats and allows for customized editing. Additionally, it features simultaneous comparison of multiple datasets on a single screen, significantly enhancing data interpretation efficiency and report-generation flexibility, thereby fully meeting the requirements of scientific research, quality control, and compliance.

    1 High repeatability

    The NKT2020-L boasts excellent repeatability; its measurement results remain highly consistent across multiple experiments, with error margins typically kept within an extremely narrow range. This outstanding repeatability stems from the instrument’s meticulously designed optical system and stable laser source, which ensure that the conditions for collecting particle-scattered light signals are identical every time a test is performed. Whether analyzing consecutive batches of samples or measuring the same sample at different time points, the laser particle size analyzer consistently delivers stable and reliable particle size distribution data. It effectively eliminates the impact of human operational variability and environmental fluctuations on the results, providing robust data support for quality control in both scientific research and industrial production.

     1 High accuracy and resolution

    The NKT2020-L boasts excellent accuracy and resolution. Thanks to its precise optical system and advanced data-processing algorithms, it can perform highly accurate particle-size distribution measurements on particulate samples. In terms of accuracy, this instrument employs a stable laser source that ensures uniform and consistent beam intensity. Coupled with a sophisticated detector array, it can keep measurement errors within an extremely narrow range—typically within ±0.5%—thus accurately reflecting the true particle-size characteristics of the sample. As for resolution, the laser particle-size analyzer can clearly distinguish between particle populations of different sizes, even detecting subtle differences in particle size with remarkable effectiveness.

  • Scope of Application

    • Industrial Minerals and Powders: Non-metallic powders such as heavy calcium carbonate, talc, and kaolin; metal powders including aluminum, copper, and rare earth metals; building material raw materials such as cement, ceramic powder, and graphite powder.
    • Energy and Chemical Materials: Cathode and anode materials for lithium batteries, catalysts, phosphors, rubber and plastic additives (in powder form), powder coatings, etc.;
    • Pharmaceuticals and Biologics: Active Pharmaceutical Ingredients (APIs) in powder form, micro-pills, ultrafine Chinese medicinal powders, spray-dried formulations, and more;
    • Food and Daily Chemicals: Starch, protein powder, powdered pigments, dye powders, powdered cosmetic ingredients, and more;
    • Environment and Geology: Dust, aerosols, soil particles, dried sediment samples, etc.;
    • Other typical dry-process applications include particulate samples—such as metal micropowders, 3D printing powders, laser cladding powders, gunpowder powders, and magnetic material powders—that are sensitive to moisture or need to remain in a dry state.

Certification


High-tech Enterprise Certificate

High-tech Enterprise Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

CE certification

CE certification

Factory


4

4

3

3

2

2

1

1

Exhibition event


4

4

3

3

2

2

1

1

FAQ



According to our sales policy, 30% of the wire transfer deposit should be paid before the order, and the remaining 70% should be completed before shipment. Before the final payment, we can provide you with real photos or videos of the goods.

Yes, but it requires sample-specific validation. Variations in optical design, dispersion efficiency, and deconvolution algorithms between different analyzers mean results will not automatically align across every material.

If you’re interested in this product, please fill out the following information and submit it to us. We’ll arrange for an expert to contact you as soon as possible!

Related products

Related products