Product Center

Professional manufacturer of intelligent analytical instruments

NKT5100-H
+
  • NKT5100-H

NKT5100-H

Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 780mm × 280mm × 300mm Product Features: One-click intelligent testing for the entire process; Error-operation protection system; High-transmittance membrane sample window; Professional-grade dustproof and shockproof design; Intelligent optical path dual-centering system; Intelligent ultrasonic dry-run protection system.

Keywords:

NKT5100-H

  • Description
  • Parameter
  • Technology
  • Applicable scope
    • Commodity name: NKT5100-H

    Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 780mm × 280mm × 300mm Product Features: One-click intelligent testing for the entire process; Error-operation protection system; High-transmittance membrane sample window; Professional-grade dustproof and shockproof design; Intelligent optical path dual-centering system; Intelligent ultrasonic dry-run protection system.

    Product Overview

    The NKT5100-H wet laser particle size analyzer is an economical particle size analysis instrument designed for a wide range of users. It adopts the internationally advanced Mie scattering theory and a convergent-beam Fourier transform optical path design, combined with a unique dual-lens technology featuring both a Fourier transform lens and a filtering lens, which significantly enhances the instrument’s measurement accuracy. Paired with a high-density array detector and a seamless full-range testing method, this instrument ensures outstanding accuracy and repeatability in its test results. Equipped with a distinctive wet-circulation dispersion system featuring a pipeline design with zero residual accumulation, the instrument effectively prevents large particles from settling during testing and avoids waste liquid buildup after the test is completed. This innovative design not only guarantees accurate measurements across different samples but also greatly improves the reproducibility of consecutive repeated tests, ensuring that every measurement yields true and reliable particle size data.

  • Product Parameters

    Measurement principle

    Mie Scattering Principle for the Full Measurement Range

    Particle size range

    0.1 μm – 800 μm

    Detection system

    76-channel uniform cross-array and area-compensated multi-orientation array

    Laser device

    High-power fiber-coupled semiconductor laser with a wavelength of 635 nm and a maximum output power of 20 milliwatts.

    Optical model

    Full-range complete Mie scattering theory, including high-concentration multiple-scattering dynamic compensation technology.

    Filtering method

    Dual-lens filtering technology: Fourier transform lens + filtering lens

    Collect the motherboard

    High-speed acquisition motherboard (10,000 times/second)

    Concentration range

    Minimum shading rate: 3%; maximum shading rate: 90% (optical density)

    Sample pool

    Processed with a special coating technology, optical signal transmittance > 99.7%

    Protection function

    Ultrasound dry-run protection, liquid-level sensor, overflow pipe, and no response to misoperations.

    Ultrasound power

    50W, ultrasonic dry-run protection

    Optical centering

    Mechanical Center + Optical Center Dual-Positioning Fully Automatic Centering System

    Measure time

    Typical value < 10 seconds

    Measurement accuracy

    Accuracy and repeatability Dv50 are both better than ±0.5% (NIST-traceable standard sample).

    Measurement method

    SOP editable fully automatic measurement

    Ambient temperature

    0°C–45°C

    Environmental humidity

    10%-85% relative humidity (no condensation)

    Power requirements

    220V (±20V), 50Hz–60Hz

    Implementation standard

    ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022

    External dimensions

    780mm × 280mm × 300mm

    Instrument weight

      38kg

  • Technical Explanation

    1 One-click intelligent testing for the entire process—extremely simplified operation, consistent results:

    The instrument comes with a built-in, editable Standard Operating Procedure (SOP) that can be initiated with just one click, automatically executing the entire testing process—from water intake and bubble removal to background measurement, sample dispersion, data acquisition, storage, and cleaning. By delegating complex operations to the instrument itself, operators need only place the sample into the device, significantly reducing reliance on operator experience. This mode completely eliminates the inevitable variations and subjective errors inherent in manual operations, ensuring high consistency and reliability of test data across different operators and at different time points—perfectly aligning with GLP laboratory standards and quality traceability system requirements.

    1 Sample design with zero residue—zero residual, real data:

    Employing an innovative flow-path system design, we have comprehensively optimized the pipeline layout and drainage structure. At the heart of the system is a self-cleaning circulation pump equipped with patented technology; its unique structural design and hydrodynamic optimization ensure that, upon completion of testing, no residual liquid remains in either the pipelines or the pump body. This breakthrough completely resolves the longstanding challenge of cross-contamination caused by sample residues in conventional instruments, thereby guaranteeing—right from the hardware level—the independence and absolute accuracy of each test result and significantly enhancing the instrument’s test reproducibility and reliability.

    1 High-transmittance coated sample windows—exceptional substrate, precision coating:

    The core optical components are made from highly wear-resistant glass produced by Corning in the U.S., complemented by a specialized optical coating process. Their wear resistance exceeds that of conventional sample windows by more than five times, greatly extending their service life. The coating technology strictly controls the signal scattering loss rate to below 0.01%, significantly boosting the effective signal transmittance by 20% and laying a solid foundation for the ultra-high accuracy of core data.

    1 Intelligent Optical Path Dual-Alignment System—Key Calibration, Dynamic Stability:

    Pioneering a dual-centering optical path system that integrates both mechanical and optical centering technologies. This system enables one-click startup and instantaneous, precise centering, completely eliminating the need for tedious manual adjustments. Moreover, the system continuously monitors and automatically maintains the optimal state of the optical path throughout the entire operation, ensuring long-term stability of measurement results and high instrument reliability—truly making it effortless and worry-free.

    1 Professional-grade dustproof and shockproof design—unafraid of environmental fluctuations, ensuring data consistency at all times:

    Equipped with a professional, integrated, sealed dust-proof system and an anti-vibration design, this product effectively prevents external dust from entering and isolates the transmission of vibrations. This design ensures long-term stability and precise focusing of the core optical path system, eliminating the need for manual adjustment of the detector position. As a result, maintenance frequency is significantly reduced, guaranteeing ultra-high repeatability and reliability of measurement results—even under challenging industrial conditions.

    1 Misoperation Protection System—Smart Protection, Fearless of Mistakes:

    Equipped with a comprehensive, intelligent fail-safe protection system that integrates hardware interlocks and software-based intelligent detection. The system can detect non-compliant operations in real time and immediately trigger proactive alerts and interrupt execution. It will not respond to invalid commands at all, thereby fundamentally preventing instrument hardware damage caused by human error and greatly enhancing the device’s durability and operational safety, allowing you to use it with complete peace of mind.

    1 Smart Ultrasonic Dry-Run Protection System—Intelligent Sensing, Proactive Protection:

    Equipped with an intelligent ultrasonic dry-run protection system, this device can monitor the status of the dispersion medium in real time. When the system detects that there is no liquid in the sample cell, it will automatically prevent the ultrasonic generator from starting up or immediately stop operation. This fundamentally prevents damage to the ultrasonic system caused by running it without any liquid, significantly enhancing the equipment’s reliability and service life.

    1 Fully automatic bubble-free system—innovative flow path design enhances operational efficiency:

    Employing fully automatic bubble-free flow path technology, and through integrated optimization of the inlet, outlet, and circulation systems, we have fundamentally eliminated the issue of air pockets in the pipelines. Throughout the entire testing process, no air-removal procedures are required, effectively preventing bubble interference and significantly enhancing detection efficiency and data accuracy.

    1 Intelligent Multi-dimensional Reporting and Analytics System—Flexible, Efficient, Intelligent, and Intuitive:

    Equipped with professional-grade particle size analysis software, this system integrates a robust database and a multi-dimensional reporting system. It supports exporting reports in multiple formats and allows for custom editing. Additionally, it features simultaneous comparison of multiple datasets on a single screen, significantly enhancing data interpretation efficiency and report-generation flexibility, thereby fully meeting the requirements of scientific research, quality control, and compliance.

    1 High repeatability:

    The NKT5100-H boasts excellent repeatability; its measurement results remain highly consistent across multiple experiments, with error margins typically kept within extremely narrow ranges. This outstanding repeatability stems from the instrument’s meticulously designed optical system and stable laser source, which ensure that the conditions for collecting particle-scattered light signals are identical every time a test is performed. Whether analyzing consecutive batches of samples or measuring the same sample at different time points, the laser particle size analyzer consistently delivers stable and reliable particle size distribution data, effectively minimizing the impact of human operational variability and environmental fluctuations on the results. This provides robust data support for quality control in both scientific research and industrial production.

    • Industrial Minerals and Powders: Non-metallic powders such as heavy calcium carbonate, talc, and kaolin; non-metallic powders including aluminum, copper, and rare earth elements; building material raw materials such as cement, ceramics, and graphite.
    • Energy and Chemical Materials: Cathode and anode materials for lithium batteries, catalysts, phosphors, rubber and plastic additives, drilling fluids, and more;
    • Pharmaceuticals and Biologics: Active Pharmaceutical Ingredients, Mini-tablets, Ultrafine Powders of Traditional Chinese Medicine, Suspension Concentrates for Pesticides, Spray Formulations, etc.;
    • Food and Daily Chemicals: Dairy products, starch, protein particles, pigments, dyes, coatings, inks, etc.;
    • Environment and Geology: Particle detection of sediment, deposits, dust, aerosols, water treatment flocculants, and other particulates.

Certification


High-tech Enterprise Certificate

High-tech Enterprise Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

CE certification

CE certification

Factory


4

4

3

3

2

2

1

1

Exhibition event


4

4

3

3

2

2

1

1

FAQ



According to our sales policy, 30% of the wire transfer deposit should be paid before the order, and the remaining 70% should be completed before shipment. Before the final payment, we can provide you with real photos or videos of the goods.

Yes, but it requires sample-specific validation. Variations in optical design, dispersion efficiency, and deconvolution algorithms between different analyzers mean results will not automatically align across every material.

If you’re interested in this product, please fill out the following information and submit it to us. We’ll arrange for an expert to contact you as soon as possible!

Related products

Related products