NKT5600-H
+
  • NKT5600-H

NKT5600-H

Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 700mm × 495mm × 300mm Product Features: Intelligent Active Anti-Fog System LIMS Laser Intelligent Management System Ultra-High-Speed Signal Acquisition System Intelligent Real-Time Dew Point Monitoring and Early Warning System Single-Light-Path Dual-Objective Optical System Sixth-Generation Long-Life, High-Stability Photoelectric Detector

Keywords:

NKT5600-H

  • Description
  • Parameter
  • Technology
  • Applicable scope
    • Commodity name: NKT5600-H

    Implementation Standards: ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022 External Dimensions: 700mm × 495mm × 300mm Product Features: Intelligent Active Anti-Fog System LIMS Laser Intelligent Management System Ultra-High-Speed Signal Acquisition System Intelligent Real-Time Dew Point Monitoring and Early Warning System Single-Light-Path Dual-Objective Optical System Sixth-Generation Long-Life, High-Stability Photoelectric Detector

    Product Overview

    The NKT5600-H intelligent fully automatic laser particle size analyzer embodies NKT’s 15 years of technological innovation and professional expertise in the field of particle characterization. It integrates multiple innovative technologies and patented solutions, achieving a breakthrough upgrade in particle size measurement performance. The instrument features an advanced dual-lens optical system coupled with a new-generation array of forward, side, and backward detectors, significantly expanding the measurement range and comprehensively enhancing overall performance. The hardware system has been completely upgraded, equipped with a fifth-generation ultra-high-speed signal acquisition motherboard that greatly improves the completeness and accuracy of scattered light signal collection, ensuring data is authentic and reliable. The instrument’s exterior adopts an internationally advanced one-step molding process using argon-gas-protected injection molding, resulting in a lightweight body that combines elegant texture with exceptional corrosion resistance. Built-in, NKT’s self-developed Laser Intelligent Management System (LIMS) can dramatically extend the laser’s service life, approaching its theoretical infinite lifespan and effectively reducing user maintenance costs. An innovative intelligent anti-fogging system continuously monitors changes in ambient temperature and humidity, providing millisecond-level rapid response to fog formation on the sample window, thereby completely eliminating measurement deviations caused by fogging. The unique wet-method circulation dispersion system features a pipe design with zero residue, effectively preventing large particle deposition and residual waste liquid after testing. This not only ensures accurate testing for various sample types but also significantly enhances the consistency of repeated measurements, guaranteeing that every test yields true and reliable particle size analysis results.

  • Measurement principle

    Mie Scattering Principle for the Full Measurement Range

    Particle size range

    0.01 μm – 1500 μm (full-range testing)

    Detection system

    96-channel uniform cross-over and area-compensated multi-orientation laser array

    Laser device

    High-power fiber-coupled semiconductor laser with a wavelength of 635 nm and a maximum output power of 20 milliwatts.

    Laser Management

    LIMS Laser Intelligent Management System

    Optical model

    Mie scattering theory over the full measurement range, including a high-concentration multiple-scattering dynamic compensation technique.

    Filtering method

    Dual-lens filtering technology: Fourier transform lens + filtering lens

    Collect the motherboard

    16-bit, 200 kbps ultra-high-speed acquisition motherboard

    Concentration range

    Minimum shading rate: 3%, maximum shading rate: 90% (optical density)

    Sample pool

    Processed with a special coating technology, optical signal transmittance > 99.7%.

    Protection function

    Ultrasound dry-run protection, liquid-level sensor, overflow pipe, and no response to misoperations.

    Ultrasound power

    50W/60W optional; adjustable-power ultrasonic available as an option.

    Alignment system

    Mechanical Center + Optical Center Dual-Positioning Fully Automatic Centering System

    Measure time

    Typical value < 10 seconds

    Measurement accuracy

    Accuracy and repeatability Dv50 are both better than ±0.5% (NIST-traceable standard samples).

    Measurement method

    SOP editable fully automatic measurement

    Ambient temperature

    0°C–45°C

    Environmental humidity

    10%-85% relative humidity (no condensation)

    Power requirements

    220V (±20V), 50Hz–60Hz

    Implementation standard

    ISO 13320-2020, GB/T 19077-2024, GB/T 41949-2022

    External dimensions

    820mm × 310mm × 330mm

    Instrument weight

     32kg

  • 1 One-click intelligent testing for the entire process—extremely simplified operation, consistent results.

    The instrument features a built-in, editable Standard Operating Procedure (SOP) that, with just one click, automatically executes the entire testing process—from water intake and bubble-removal background measurement, to sample dispersion, data acquisition, storage, and cleaning. By delegating complex operations to the instrument itself, operators need only place the sample into the device, significantly reducing reliance on operator experience. This mode completely eliminates the inevitable variations and subjective errors inherent in manual operations, ensuring high consistency and reliability of test data across different operators and at different time points—perfectly aligning with GLP laboratory standards and quality traceability system requirements.

    1 LIMS Laser Intelligent Management System—Smart Optical Paths, Enduring and Stable

    The system integrates an advanced LIMS laser intelligent management system, enabling precise and intelligent control of laser sources. The system can monitor the optical path status in real time, instantly activate the laser upon receiving a test command, and quickly reach a stable operating state within 3 seconds—greatly reducing wait times and boosting detection efficiency. After measurement is complete, the system automatically shuts down the laser, completely eliminating unnecessary standby power consumption. This intelligent management technology effectively prevents light degradation caused by prolonged laser operation, significantly extending the service life of core components. In theory, the design allows lasers to operate without replacement for their entire lifespan, delivering customers unparalleled reliability and ultra-low maintenance costs.

    1 Sample Window Second-Level Quick-Change System—Revolutionary Design, Second-Level Operation

    Equipped with a revolutionary sample window quick-change mechanism, this device features a user-friendly snap-lock and guiding structure design. Without the need for any tools, users can independently complete the entire process of removing and installing the sample window in just 10 seconds, greatly simplifying the maintenance procedure, significantly reducing instrument maintenance time, and ensuring continuous operational efficiency in high-throughput testing environments.

    1 Intelligent Multi-dimensional Reporting and Analytics System—Flexible, Efficient, Intelligent, and Intuitive

    Equipped with professional-grade particle size analysis software, this system integrates a robust database and a multi-dimensional reporting system. It supports exporting reports in multiple formats and allows for customized editing. Additionally, it features simultaneous comparison of multiple datasets on a single screen, significantly enhancing data interpretation efficiency and report-generation flexibility, thereby fully meeting the requirements of scientific research, quality control, and compliance.

    1 Single-optical-path dual-lens optical system—pure, pristine light signals with ultimate sensitivity.

    This design employs an innovative dual-lens system that combines a Fourier-transform lens with a filtering lens. The technology establishes a pure, single-optical-path detection environment, efficiently eliminating unnecessary stray light interference from the incident optical signal and significantly enhancing the purity of the optical background. As a direct result, the signal-to-noise ratio is dramatically improved, enabling the instrument to achieve exceptional sensitivity and resolution in detecting scattered light signals from even the tiniest particles in the sample. This greatly enhances the measurement’s sensitivity and accuracy, making it particularly well-suited for high-precision analysis of nanomaterials and low-concentration samples.

    1 Ultra-High-Speed Signal Acquisition System—Capturing Transients, Gaining Insights at the Nanoscale

    Equipped with a fifth-generation ultra-high-speed signal acquisition motherboard, the system achieves an ultra-high sampling rate of 10,000 times per second. Thanks to this hardware-level breakthrough, the system can complete comprehensive, lossless, and synchronous capture of all particle-scattered light signals within the fleeting 0.1-second interval when a sample passes through the measurement zone. This completely resolves the issue of signal omissions caused by the random orientation of particles, thereby ensuring unparalleled accuracy and high repeatability in particle size distribution results.

    1 Sixth-generation long-life, highly stable photoelectric detector—crafted with meticulous R&D, ensuring consistent precision.

    The core photoelectric detector array is equipped with NKT’s independently developed sixth-generation highly stable photoelectric detector. It uses specially selected, high-performance raw materials imported from Germany and boasts exceptional antioxidant and anti-aging properties, ensuring that the photoelectric conversion efficiency remains virtually unchanged for up to ten years. The detector’s theoretical lifespan is synchronized with that of the entire instrument, eliminating the need for replacement throughout its lifetime and fundamentally guaranteeing long-term consistency and accuracy of the instrument’s measurement data, as well as extremely low lifetime maintenance costs.

    1 Smart Active Anti-Fog System—Intelligent Sensing, Proactive Fog Removal

    Equipped with an intelligent, active anti-fog system, this device can monitor changes in ambient temperature and humidity in real time, providing millisecond-level warnings and rapid responses to the risk of fogging on the sample window. Thanks to its active defogging technology, condensation on optical windows is completely eliminated, thereby removing any distortion of scattered light signals caused by fogging and ensuring that measurement data remains consistently accurate and reliable.

    1 Intelligent Optical Path Dual-Alignment System—Key Calibration, Dynamic Stability Enhancement

    Pioneering a dual-centering optical path system that integrates both mechanical and optical centering technologies. This system enables one-click startup and instantaneous, precise centering, completely eliminating the need for tedious manual adjustments. Moreover, the system continuously monitors and automatically maintains the optimal state of the optical path throughout the entire operation, ensuring long-term stability of measurement results and high instrument reliability—truly making it effortless and worry-free.

    1 Sample design with zero residue—zero residues, real data.

    An innovative flow-path system design has been adopted, enabling a comprehensive optimization of pipeline layout and drainage structure. At the heart of this system is a self-cleaning circulation pump featuring patented technology. Its unique structural design and hydrodynamic optimization ensure that, upon completion of testing, no residual liquid remains in either the pipelines or the pump body. This breakthrough completely resolves the longstanding challenge of cross-contamination caused by sample residues in conventional instruments, thereby guaranteeing the independence and absolute accuracy of each test result from the very hardware level. As a result, the instrument’s test reproducibility and reliability have been significantly enhanced.

    1 Professional-grade dustproof and shockproof design—unafraid of environmental fluctuations, ensuring data remains consistently reliable.

    Featuring a professional, integrated, sealed dust-proof system and an anti-vibration design, this solution effectively prevents external dust from entering and minimizes the transmission of vibrations. This design ensures long-term stability and precise focusing of the core optical path system, eliminating the need for manual adjustment of the detector position. As a result, maintenance frequency is significantly reduced, guaranteeing ultra-high repeatability and reliability of measurement results—even under challenging industrial conditions.

    1 Dispersion Agent Automatic Filling System—Precision Intelligent Control, Simplifying the Complex

    An optional high-precision dispersant automatic addition system is available. This system integrates seamlessly with the instrument’s intelligent SOP (Standard Operating Procedure), allowing it to automatically and quantitatively add dispersants during the testing process according to pre-set methods. This completely eliminates random errors caused by manual addition, ensuring highly consistent sample pretreatment and significantly enhancing the reliability, reproducibility of test results, and the level of operational automation.

    1 Misoperation Protection System—Smart Protection, Fearless of Mistakes

    Equipped with a comprehensive, intelligent fail-safe protection system that integrates hardware interlocks and software-based intelligent detection. The system can detect non-compliant operations in real time and immediately trigger proactive alerts and interrupt execution. It will not respond to invalid commands at all, thereby fundamentally preventing instrument hardware damage caused by human error and significantly enhancing the device’s durability and operational safety, allowing you to use it with complete peace of mind.

    1 Intelligent Real-Time Dew Point Monitoring and Early Warning System—Gain Insight, Prevent Problems Before They Arise

    Specifically designed to ensure the measurement accuracy of laser particle size analyzers even in harsh environmental conditions, this system integrates high-precision sensors with intelligent algorithms. It can monitor in real time the microenvironmental conditions within the instrument’s core optical system and proactively predict the risk of condensation. By issuing timely risk-control alerts, it enables proactive intervention before physical phenomena occur, fundamentally preventing light scattering data deviations caused by condensation on the optical window and ensuring the authenticity and accuracy of particle size distribution results.

    1 High repeatability

    The NKT5600-H boasts excellent repeatability; its measurement results remain highly consistent across multiple experiments, with error margins typically kept within an extremely narrow range. This outstanding repeatability stems from the instrument’s meticulously designed optical system and stable laser source, which ensure that the conditions for collecting particle-scattered light signals remain identical every time a test is performed. Whether analyzing consecutive batches of samples or measuring the same sample at different time points, the laser particle size analyzer consistently delivers stable and reliable particle size distribution data. It effectively eliminates the impact of human operational variability and environmental fluctuations on the results, providing robust data support for quality control in both scientific research and industrial production.

    1 High accuracy and resolution

    The NKT5600-H boasts excellent accuracy and resolution. Thanks to its precise optical system and advanced data-processing algorithms, it can perform highly accurate particle-size distribution measurements on particulate samples. In terms of accuracy, this instrument employs a stable laser source that ensures uniform and consistent beam intensity. Coupled with a sophisticated detector array, it can keep measurement errors within an extremely narrow range—typically within ±0.5%—thus accurately reflecting the true particle-size characteristics of the sample. As for resolution, the laser particle-size analyzer can clearly distinguish between particle populations of different sizes, even detecting subtle differences in particle size with remarkable effectiveness. Its resolution can reach as fine as 0.01 micrometers, making it capable of meeting measurement requirements across a broad particle-size range—from nanometer-scale to millimeter-scale particles.

    • Industrial Minerals and Powders: Non-metallic powders such as heavy calcium carbonate, talc, and kaolin; non-metallic powders including aluminum, copper, and rare earth elements; building material raw materials such as cement, ceramics, and graphite.
    • Energy and Chemical Materials: Cathode and anode materials for lithium batteries, catalysts, phosphors, rubber and plastic additives, drilling fluids, and more;
    • Pharmaceuticals and Biologics: Active Pharmaceutical Ingredients, Microtablets, Ultrafine Powders of Traditional Chinese Medicine, Suspension Concentrates for Pesticides, Spray Formulations, etc.;
    • Food and Daily Chemicals: Dairy products, starch, protein particles, pigments, dyes, coatings, inks, etc.;
    • Environment and Geology: Particle detection of sediment, deposits, dust, aerosols, water treatment flocculants, and other particulates.

Certification


High-tech Enterprise Certificate

High-tech Enterprise Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

Quality Management System Certification Certificate

CE certification

CE certification

Factory


4

4

3

3

2

2

1

1

Exhibition event


4

4

3

3

2

2

1

1

FAQ



According to our sales policy, 30% of the wire transfer deposit should be paid before the order, and the remaining 70% should be completed before shipment. Before the final payment, we can provide you with real photos or videos of the goods.

Yes, but it requires sample-specific validation. Variations in optical design, dispersion efficiency, and deconvolution algorithms between different analyzers mean results will not automatically align across every material.

If you’re interested in this product, please fill out the following information and submit it to us. We’ll arrange for an expert to contact you as soon as possible!